750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz

Product Details
Customization: Available
After-sales Service: Global Service
Warranty: 12 Months
Manufacturer/Factory, Trading Company
Gold Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Low MOQ
The MOQ for the supplier's products is 1
Full Customization
The supplier provides full customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (7)
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
  • 750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
MTU
Type
Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Air Cooled
Output Type
AC Three Phase
Speed
1500rpm
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Ordinary
Excitation Mode
Brushless Exciting
Model
Bic-M825
Voltage
400V
Frequency
50Hz
Standby Power
825kVA
Prime Power
750kVA
Engine
Mtu
Alternator
Customized
Transport Package
Open Type
Specification
4500*2100*2080 mm
Trademark
Banland
Origin
China
HS Code
8502110000
Production Capacity
4000sets/Year

Product Description

Product Description

825KVA 12V2000G65 engine S5L1D-H1 best diesel power electric generator generating set for MTU.

750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz


750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz 
Product Parameters
Powered by MTU | 400V, 1500RPM, 50Hz
Banland   Standby Prime Engine Alternator Dimension mm Dimension mm
Model kVA kVA Model STF Open Type Silent Type
BIC-M825 825 750 12V2000G65 S5L1D-H1 4500*2100*2080 ISO 20'ft GP
BIC-M880 880 800 12V2000G65 S6L1D-C4 4500*2100*2080 ISO 20'ft GP
BIC-M1000 1000 910 16V2000G25 S6L1D-D4  4500*2100*2080 ISO 20'ft GP
BIC-M1100 1100 1000 16V2000G65 S6L1D-E4 4500*2100*2080 ISO 20'ft GP
BIC-M1250 1250 1135 18V2000G65 S6L1D-F4 4600*2100*2300 ISO 20'ft GP
BIC-M1375 1375 1250 18V2000G26F  S6L1D-G4 3960*1835*2260 ISO 20'ft HQ
BIC-M1375 1375 1250 18V2000G76F S6L1D-G4 3960*1835*2260 ISO 20'ft HQ
BIC-M1500 1500 1400 12V4000G14RF S6L1D-H4 3960*1835*2260 ISO 20'ft HQ
BIC-M1700 1700 1550 12V4000G23 S7L1D-C4 3960*1835*2260 ISO 20'ft HQ
BIC-M1800 1800 1640 12V4000G23 S7L1D-D4 3960*1835*2260 ISO 40'ft HQ
BIC-M2000 2000 1850 12V4000G63 S7L1D-F41 3980*1845*2270 ISO 40'ft HQ
BIC-M2250 2250 2050 16V4000G23 S7L1D-G41 4790*1845*2270 ISO 40'ft HQ
BIC-M2500 2500 2250 16V4000G63 S7L1D-H41 5450*1845*2560 ISO 40'ft HQ
BIC-M2750 2750 2500 20V4000G23 S7L1D-J4  5650*1900*2650 ISO 40'ft HQ
BIC-M3000 3000 2750 20V4000G63 LSA52.3 UL16( LEORY) 5700*1950*2700 ISO 40'ft HQ
BIC-M3250 3250 3000 20V4000G63L LSA 53.2M9   (LEORY) 5750*1980*2750 ISO 40'ft HQ
BIC-M3600 3575 3250 20V4000G94F  LSA 53.2M12  (LEORY) 5750*1980*2750 ISO 40'ft HQ
BIC-M1700 1700 1550 12V4000G14F  S7L1D-C4 3960*1835*2260 ISO 40'ft HQ
BIC-M1800 1800 1640 12V4000G74F S7L1D-D4 3960*1835*2260 ISO 40'ft HQ
BIC-M2000 2000 1850 12V4000G24F S7L1D-F4 3980*1845*2270 ISO 40'ft HQ
BIC-M2250 2250 2050 16V4000G14F S7L1D-G4 4790*1845*2270 ISO 40'ft HQ
BIC-M2500 2500 2275 16V4000G24F S7L1D-J4  5450*1845*2560 ISO 40'ft HQ
BIC-M2750 2750 2500 20V4000G14F  S7L1D-J4  5650*1900*2650 ISO 40'ft HQ
BIC-M3000 3000 2750 20V4000G63F LSA52.3 UL16(LEORY) 5700*1950*2700 ISO 40'ft HQ
BIC-M3250 3300 3000 20V4000G63LF LSA 53.2M9  (LEORY) 5750*1980*2750 ISO 40'ft HQ


 
Powered by MTU | 440V, 1800RPM, 60Hz
Banland   Standby Prime Engine Alternator Dimension mm Dimension mm
Model kVA kVA Model STF Open Type Silent Type
BIC-M880-60 1000 910 12V2000G85 S6L1D-C4 4000*1750*2050 ISO 20'ft GP
BIC-M1000-60 1137 1025 16V2000G45 S6L1D-D4 4500*2100*2080 ISO 20'ft GP
BIC-M1100-60 1265 1150 16V2000G85 S6L1D-E4 4500*2100*2080 ISO 20'ft GP
BIC-M1250-60 1450 1338 18V2000G85  S6L1D-F4 4600*2100*2300 ISO 20'ft GP
BIC-M1350-60 1500 1362 18V2000G85 S6L1D-G4 4600*2100*2300 ISO 20'ft GP
BIC-M1700-60 NA 1700 12V4000G14S S7L1D-F4 3960*1835*2260 ISO 20'ft HQ
BIC-M1800-60 2000 NA 12V4000G74S S7L1D-F4 3960*1835*2260 ISO 20'ft HQ
BIC-M2000-60 2200 2000 12V4000G84S or S7L1D-F4 3980*1845*2270 ISO 40'ft HQ
12V4000G24S
BIC-M2250-60 2500 2275 16V4000G74S or S7L1D-G4 4790*1845*2270 ISO 40'ft HQ
16V4000G14S
BIC-M2500-60 2750 2500 16V4000G84S or S7L1D-H4 5400*1845*2500 ISO 40'ft HQ
16V4000G24S
BIC-M2750-60 3125 2813 20V4000G64S or ECO 46-2L 5650*1900*2650 ISO 40'ft HQ
20V4000G14S
BIC-M3000-60 3438 3125 20V4000G74S or LSA 52.3 UL16 5700*1950*2700 ISO 40'ft HQ
20V4000G24S
BIC-M3250-60 3750 3450 20V4000G94S or LSA 53.2M9 5750*1980*2750 ISO 40'ft HQ
20V4000G44S
BIC-M1700-60 NA 1700 12V4000G43 S7L1D-F4 3960*1835*2260 ISO 20'ft HQ
BIC-M1800-60 2000 NA 12V4000G43 S7L1D-F4 3960*1835*2260 ISO 20'ft HQ
BIC-M2000-60 2200 2000 12V4000G83 S7L1D-F4 3980*1845*2270 ISO 40'ft HQ
BIC-M2250-60 2500 2275 16V4000G43 S7L1D-G4 4790*1845*2270 ISO 40'ft HQ
BIC-M2500-60 2750 2500 16V4000G83 S7L1D-H4 5400*1845*2500 ISO 40'ft HQ
BIC-M2750-60 3125 2813 20V4000G43 ECO 46-2L 5650*1900*2650 ISO 40'ft HQ
BIC-M3000-60 3438 3125 20V4000G83 ECO46-VL 5700*1950*2700 ISO 40'ft HQ
(Mecc Alte)
BIC-M3250-60 3750 3450 20V4000G83LS LSA 53.1M80 5750*1980*2750 ISO 40'ft HQ
(Leroy Somer)
Detailed Photos

750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
750kVA Mtu 12V2000g65 Engine Diesel Generator 50Hz
Company Profile

Welcome to Banland, your number one source for high quality generator set. 

For us, at Banland, it has always been our endeavor to maintain the highest standards of professionalism, quality and ethics. We believe in offering high quality products that match and excel same category products from our competitors in terms of quality, price and value. Our corporate relationships and associations prove the fact that we encourage long term relationships with our suppliers as well as our clients. We not only manufacture the high quality products available in the market, but also take care to follow international guidelines and business standards suggested by our partners and demanding clients all over the world. 

We offer a wide range of generator sets. We got more than 200 types of generators are categorized into six categories: Containerized generators, diesel generators, gas generators, marine generators, quiet diesel generators, and trailer type generators. 

Our products are widely used over the world on different industries. They are used in power station, factory, bank, hospital, mining, building, hotel, station, port, oil and gas industry, data center and shipyard. 

We have office in Chongqing, China, Bangkok, Thailand, Dubai, UAE, and Miami, USA. Banland Service Teams are fast responsive to all you problem. Our distributor around the world receives extensive ongoing Banland product training. This ensures that our service agent and distributor will correctly carry out service and with banland standard, it guarantees the service quality and outcome.


 

FAQ

 

Difference in kW ratings

 

People buying diesel generators must be familiar with the kW ratings in relation to what amount of power they need their diesel generator to provide. Buying generators with less power than what is needed could be disastrous. On the other hand, you don't want to waste money buying a commercial diesel power generator that outputs more power than you need.
 

There are key terms to understand when it comes to shopping diesel power generators for sale. Buyers often hear of kW or kilowatt and kVA or kilovolt-ampere.
 

Kilowatt (kW) refers to the unit of real power while kilovolt-ampere (kVA) refers to the unit of apparent power, also known as the real power added with re-active power. The difference between the kilowatt and the kilovolt-ampere is called the power factor of the generator. The power factor is an approximate value with the kilovolt-ampere having higher value than the kilowatt value. The power factor is typically measured as 0.8.
 

Kilowatt (kW) is used when buying industrial generators in the United States while the rest of the world uses kilovolt-ampere (kVA). The kilowatt (kW) rating refers to the power output of a generator based on the engine's horsepower. The kilovolt-ampere (kVA) rating of a generator is determined by multiplying its engine's horsepower by .746. Generators typically show both ratings.  The following formula will determine kilowatt and kilovolt-ampere ratio:

            .8(pf) x 625 (kVA) = 500 kW
 

The connected load of an industrial powered generator determines its power factor, which is the ratio between kilowatts (kW) and kilovolt-ampere (kVA) of the electrical load. A generator can transfer energy more efficiently to its connected load when it has high power factor. On the other hand, a generator with lower power factor cannot efficiently transfer energy to its connected load, hence making it uneconomical to operate.
 

Different Power Ratings
 

Diesel generator power ratings are classified as standby, continuous, and prime power ratings. A standby power generator, popular for power outages, is intended for emergency situations. It is used only for the duration of the emergency, such as an outage or power transmission breakdown. 

Generators with prime power ratings have unlimited run time. They are generators that are used as the primary source of power as differentiated from standby generators that are sparingly used.
 

Generators with continuous power ratings are almost the same with prime power generators but are characterized by a base load rating. They can provide a continuous supply of power but cannot have variable loads. They also do not have the ability to handle any overload.
 

Buy exactly what you need
 

When buying a generator, one has to clearly define the purpose for which it will be needed. After that, buy your industrial generator in accordance with what will be expected from the unit.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier